{"id":6166,"date":"2021-05-06T08:54:29","date_gmt":"2021-05-06T08:54:29","guid":{"rendered":"https:\/\/www.acrn.fr\/product\/clinch-diameter-gauge-at-the-valve-a2140"},"modified":"2025-10-08T15:29:36","modified_gmt":"2025-10-08T13:29:36","slug":"mesure-de-diametre-de-valve-a2140","status":"publish","type":"product","link":"https:\/\/www.acrn.fr\/en\/product\/mesure-de-diametre-de-valve-a2140\/","title":{"rendered":"Clinch Diameter gauge at the valve A2140"},"content":{"rendered":"<div class='content-column one_half'><img decoding=\"async\" class=\"alignnone size-full wp-image-4874\" src=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png1.png\" alt=\"A2140\" width=\"400\" height=\"600\" srcset=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png1.png 400w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png1-64x96.png 64w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png1-200x300.png 200w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/div>\n<div class='content-column one_half last_column'><img decoding=\"async\" class=\"alignnone size-full wp-image-4876\" src=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png2.png\" alt=\"A2140\" width=\"400\" height=\"600\" srcset=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png2.png 400w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png2-64x96.png 64w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/05\/A2140png2-200x300.png 200w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/div><div class='clear_column'><\/div>\n<h3>Technical information<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 12.5%; text-align: center;\">Type<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Range<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Range indication<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Resolution<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Measuring force \/ Weight<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Max permissible error<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Repeteability error<\/td>\n<td style=\"width: 12.5%; text-align: center;\">Operating temperature<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 12.5%; text-align: center;\">AEROSOL<\/td>\n<td style=\"width: 12.5%; text-align: center;\">5 &#8211; 15 mm<\/td>\n<td style=\"width: 12.5%; text-align: center;\">4.75 mm &#8211; 15.25 mm<\/td>\n<td style=\"width: 12.5%; text-align: center;\">0.01 mm<\/td>\n<td style=\"width: 12.5%; text-align: center;\">1.1 &#8211; 1.5 N \/ 120 g<\/td>\n<td style=\"width: 12.5%; text-align: center;\">0.03 mm<\/td>\n<td style=\"width: 12.5%; text-align: center;\">0.02 mm<\/td>\n<td style=\"width: 12.5%; text-align: center;\">10\u00b0C &#8211; 30\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<blockquote>\n<h2 data-start=\"150\" data-end=\"453\">Valve diameter gauge<\/h2>\n<\/blockquote>\n<p data-start=\"150\" data-end=\"453\">The <strong data-start=\"153\" data-end=\"162\">A2140 <\/strong> is a precision instrument designed to measure the <strong data-start=\"206\" data-end=\"250\">diameter of aerosol valves<\/strong>. It can inspect small parts, from <strong data-start=\"320\" data-end=\"334\"> 5 to 15 mm<\/strong>, with a <strong data-start=\"345\" data-end=\"375\">fine resolution of 0.01 mm<\/strong>, guaranteeing reliable detection of the slightest dimensional variations.<\/p>\n<p data-start=\"455\" data-end=\"667\">Thanks to its <strong data-start=\"467\" data-end=\"492\">controlled tolerances<\/strong> &#8211; a <strong data-start=\"499\" data-end=\"529\">maximum error of 0.03 mm<\/strong> and <strong data-start=\"537\" data-end=\"564\">repeatability of 0.02 mm<\/strong> &#8211; this instrument offers <strong data-start=\"600\" data-end=\"664\">high reliability for industrial quality control operations<\/strong>.<\/p>\n<p data-start=\"669\" data-end=\"939\">Its <strong data-start=\"672\" data-end=\"698\">low measuring force<\/strong> (1.1 to 1.5 N) ensures precise control <strong data-start=\"739\" data-end=\"769\">without the risk of part deformation<\/strong>, while its <strong data-start=\"797\" data-end=\"845\">operating range between 10\u00b0C and 30\u00b0C<\/strong> guarantees <strong data-start=\"859\" data-end=\"893\">optimum measurement stability<\/strong> under standard operating conditions.<\/p>\n","protected":false},"featured_media":4879,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[132],"product_tag":[],"class_list":{"0":"post-6166","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dimensionnal-meausrement-for-spray","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product\/6166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media\/4879"}],"wp:attachment":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media?parent=6166"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_brand?post=6166"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_cat?post=6166"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_tag?post=6166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}