{"id":6163,"date":"2020-09-29T19:49:30","date_gmt":"2020-09-29T19:49:30","guid":{"rendered":"https:\/\/www.acrn.fr\/product\/tension-compression-test-solutions"},"modified":"2025-11-05T11:29:44","modified_gmt":"2025-11-05T10:29:44","slug":"tension-compression-bench","status":"publish","type":"product","link":"https:\/\/www.acrn.fr\/en\/product\/tension-compression-bench\/","title":{"rendered":"Mecmesin Multitest-I Compression Test Stand"},"content":{"rendered":"<p>The <strong>Multitest-i<\/strong>tensile and compression <strong>tester<\/strong> is driven by software installed on a computer. Its offers both consistency and reliability using key test parameters such as force, displacement and velocity.<\/p>\n<p><strong>Multitest single column<\/strong> test stands are the ideal solution for measuring forces up to 5 kN (1100 lbf) on a wide variety of components made from almost any material, either during normal operation or when they are pulled\/pushed to the point of deliberate failure or beakage.<\/p>\n<h3>Load cells<\/h3>\n<p>The range of interchangeable <b>ILC<\/b>s is specially adapted to the <strong>Multitest-i<\/strong>. They plug into the bench and their calibration specifications are immediately recognised by the tester, without any operator intervention.<\/p>\n<p>Each ILC sensor comes with its own calibration certificate, in accordance with national standards.<\/p>\n<h3>Software<\/h3>\n<p>At the heart of the <strong>Multitest-i system<\/strong> is the Emperor software. It runs on any Windows computer and drives the best bed motor by collecting data at an impressive 1,000 Hz from the ILC loadcell and encoder with the movement of the bed.<\/p>\n<h3>Feature details<\/h3>\n<ul>\n<li>Run to load, displacement, time or break detection<\/li>\n<li>Cyclic testing<\/li>\n<li>Repeat sections of a program<\/li>\n<li>With its intelligent control functions, it allows unlimited flexibility in carrying out your tests<\/li>\n<li>Operator prompt\/Delay\/resume test facility<\/li>\n<li>Auto-return of crosshead at end of test<\/li>\n<\/ul>\n<h3>Available tests<\/h3>\n<ul>\n<li>Compression<\/li>\n<li>Tension<\/li>\n<li>Tear<\/li>\n<li>Flexure<\/li>\n<li>Stiffness<\/li>\n<li>Friction<\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%; height: 182px;\">\n<tbody>\n<tr style=\"height: 23px;\">\n<td style=\"width: 12.5%; height: 23px; text-align: center;\"><strong>Test Frame<\/strong><\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">0.5<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2.5<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">5<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">10<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">25<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">50<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 12.5%; height: 23px; text-align: center;\"><strong>Rated capacity N<\/strong><\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">500<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1000<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2500<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">5000<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">10 000<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">25 000<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">50 000<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 12.5%; height: 23px; text-align: center;\"><strong>Rated capacity kgf<\/strong><\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">50<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">10<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">250<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">500<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1000<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2500<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">5000<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 12.5%; height: 23px; text-align: center;\"><strong>Number of ballscrews<\/strong><\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\"><\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">1<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2<\/td>\n<td style=\"width: 12.5%; height: 23px; text-align: center;\">2<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 12.5%; height: 21px; text-align: center;\"><strong>Speed mm \/ min<\/strong><\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 1000<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 1000<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 1000<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 500<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 1000<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 1000<\/td>\n<td style=\"width: 12.5%; height: 21px; text-align: center;\">1 &#8211; 400<\/td>\n<\/tr>\n<tr style=\"height: 46px;\">\n<td style=\"width: 12.5%; text-align: center; height: 46px;\"><strong>Crosshead speed accuracy<\/strong><\/td>\n<td style=\"text-align: center; height: 46px;\" colspan=\"7\">\u00b1 0.2 % of indicated speed<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 12.5%; text-align: center; height: 23px;\"><strong>Voltage<\/strong><\/td>\n<td style=\"width: 12.5%; text-align: center; height: 23px;\" colspan=\"7\">230 V AC 50 Hz or 110 V AC 60 Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<blockquote><p>Computer-controlled test frames<\/p><\/blockquote>\n<p>The Mecmesin Multitest-i range of test frames sets the standard in computer-controlled testing, operating through the power of Emperor software.<\/p>\n<ul>\n<li>Complete range from 2 N to 50,000 N<\/li>\n<li>High speed data collection &#8211; 1000 readings per second<\/li>\n<li>Auto-loadcell recognition\/configuration<\/li>\n<li>Auxiliary &#8216;event&#8221; input allows the software to recgnise when switch contact is made or broken<\/li>\n<li>IP splashproof membrane control panel with emergency stop button<\/li>\n<\/ul>\n","protected":false},"featured_media":4596,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[97],"product_tag":[],"class_list":{"0":"post-6163","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-compression-tensile-bench","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product\/6163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media\/4596"}],"wp:attachment":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media?parent=6163"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_brand?post=6163"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_cat?post=6163"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_tag?post=6163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}