{"id":6157,"date":"2021-03-31T15:01:08","date_gmt":"2021-03-31T15:01:08","guid":{"rendered":"https:\/\/www.acrn.fr\/product\/tx-mechanical-force-gauges"},"modified":"2026-04-22T14:08:27","modified_gmt":"2026-04-22T12:08:27","slug":"dynamometer-mechanics-of-traction","status":"publish","type":"product","link":"https:\/\/www.acrn.fr\/en\/product\/dynamometer-mechanics-of-traction\/","title":{"rendered":"Mechanical traction dynamometer TX"},"content":{"rendered":"<h2><strong><span style=\"color: #215876;\">Discover our TX mechanical tensile tester<\/span><\/strong><\/h2>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38A device that requires no power source and has no usage limits<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The TX requires no battery, no power supply, and no software. It is ready to use immediately, with no warm-up time or prior setup required. There is no limit on the number of tests or the duration of testing. This solution is particularly well-suited for production control stations where uptime and ease of use are top priorities.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38The maximum disengageable index<\/strong><\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The maximum index is a pointer that moves along the scale during the test and remains in position after the force is released. It allows you to read the maximum value reached without maintaining traction, which makes it easier to take measurements in situations where access to the scale is difficult during the test.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38A safety factor of 5<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The TX structure is designed to withstand five times its rated capacity without permanent deformation. This high coefficient ensures the instrument&#8217;s durability even in the event of improper use or accidental impact, and contributes to the operator&#8217;s safety.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Comes with an ACRN calibration certificate<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Each TX dynamometer comes with a calibration certificate issued by ACRN. We recommend an annual preventive calibration check, which can be performed on-site or at our metrology laboratory in Normandy.<\/p>\n<hr \/>\n<h3><strong>Specifications<\/strong><\/h3>\n<div class='content-column one_half'><ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><span style=\"color: #215876;\">Robust and economical<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><span style=\"color: #215876;\">Accuracy of + \/ &#8211; 4%.<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><span style=\"color: #215876;\"> Useful reading from 1\/10 of the measuring range<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><span style=\"color: #215876;\"> Safety coefficient 5<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><span style=\"color: #215876;\"> Disengageable maximum index<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p><\/div>\n<div class='content-column one_half last_column'><img decoding=\"async\" class=\"alignnone size-full wp-image-6767\" src=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/03\/tx.png\" alt=\"tx\" width=\"500\" height=\"450\" srcset=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/03\/tx.png 500w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/03\/tx-480x432.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 500px, 100vw\" \/><\/div><div class='clear_column'><\/div>\n<h4 style=\"text-align: center;\">TX Traction<\/h4>\n<table style=\"border-collapse: collapse; width: 100%; height: 214px;\">\n<tbody>\n<tr style=\"height: 53px;\">\n<td style=\"width: 33.3333%; height: 53px; text-align: center;\">Model<\/td>\n<td style=\"width: 33.3333%; height: 53px; text-align: center;\">Scope (daN)<\/td>\n<td style=\"width: 33.3333%; height: 53px; text-align: center;\">Graduation (daN)<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 60<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 60<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">1<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 100<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 100<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">1<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 150<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to150<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">2<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 200<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 200<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">2<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 300<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 300<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">5<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 400<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 400<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">4<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">TX 600<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">0 to 600<\/td>\n<td style=\"width: 33.3333%; height: 23px; text-align: center;\">20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Options<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 100%;\">Carrying case<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Delivered with:<\/h3>\n<ul>\n<li>ACRN calibration certificate<\/li>\n<li>A user manual<\/li>\n<\/ul>\n<hr \/>\n<h2><strong><span style=\"color: #215876;\">Applications and Industries<\/span><\/strong><\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The TX mechanical dynamometer is used in many industrial sectors for quality control and force verification applications:<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Manufacturing and Assembly<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Measurement of pull-off force and tensile strength of welds, adhesive bonds, or mechanical fasteners on production lines or in design offices.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Packaging and Packaging Materials<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">measuring the force required to open packaging, testing the mechanical strength of closures, and verifying crimping or clipping forces.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Construction and Lifting<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Verification of tension forces on cables, straps, or anchoring systems, using the sturdy lifting eyes integrated into the housing.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Maintenance and Field Operations<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Thanks to its lack of a power supply and its weather resistance, the TX is ideal for inspections in harsh environments or outdoors.<\/p>\n<h3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #95cceb;\"><strong>\ud83d\udd38Calibration and Metrology<\/strong> <\/span><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">used as a transfer standard in metrology laboratories for the verification of other force measurement instruments.<\/p>\n<hr \/>\n<h2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #215876;\"><strong>Best practices for measurement<\/strong><\/span><\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">To ensure accurate results, make sure the dynamometer is perfectly aligned with the pull axis before applying force. Use appropriate shackles in the lifting eyes\u2014never apply force off-axis. Wait until the reading has completely stabilized before taking the measurement. Stand facing the graduated scale to avoid parallax errors.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The valid reading begins at 1\/10 of the measurement range: for a TX 100, the measurement is reliable starting at 10 daN. Below this value, the measurement uncertainty is too high to guarantee the stated accuracy of \u00b14%.<\/p>\n<hr \/>\n<h2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #215876;\"><strong>Why choose a mechanical dynamometer over an electronic one?<\/strong><\/span><\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The TX mechanical dynamometer is particularly well-suited for situations where simplicity and durability take precedence over connectivity. Unlike electronic force gauges, it requires no batteries or electronic maintenance and operates under extreme temperature or humidity conditions. It is the preferred choice for field control stations, ATEX environments, or simply for users who want a reliable, cost-effective tool that isn&#8217;t tied to any specific technology. Its annual calibration by ACRN ensures the metrological traceability required by ISO 9001 quality management systems.<\/p>\n<hr \/>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #000000;\"><strong>Also worth checking out<\/strong><\/span><\/p>\n<blockquote class=\"ml-2 border-l-4 border-border-300\/10 pl-4 text-text-300\">\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><span style=\"color: #000000;\"><strong>Do you need an additional instrument or accompaniment?<\/strong><\/span><\/p>\n<ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\"><span style=\"color: #000000;\">The<\/span> <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.acrn.fr\/en\/product\/dynamometer-mechanical-compression\/\">CX Mechanical Compression Dynamometer<\/a><\/strong> <span style=\"color: #000000;\">works on the same principle as the TX but with compression\u2014ideal if you need to cover both types of performance with instruments in the same range.<\/span><\/li>\n<li class=\"whitespace-normal break-words pl-2\"><span style=\"color: #000000;\">The<\/span> <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.acrn.fr\/en\/product\/electronic-dynamometer-epx-t\/\">EPX-T Digital Scale<\/a><\/strong><span style=\"color: #000000;\"> is the digital alternative to the TX: digital display, data output, and measurement memory for applications requiring enhanced traceability.<\/span><\/li>\n<li class=\"whitespace-normal break-words pl-2\"><span style=\"color: #000000;\">Ours<\/span> <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.acrn.fr\/en\/compression-tensile-bench\/\">Tension and compression testing machines<\/a><\/strong> <span style=\"color: #000000;\">are the solution for motorized repetitive testing with force-displacement curves and software control. <\/span><\/li>\n<li class=\"whitespace-normal break-words pl-2\"><span style=\"color: #000000;\">Our service<\/span> <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.acrn.fr\/en\/calibration-metrology\/\">Calibration &amp; Metrology<\/a><\/strong> <span style=\"color: #000000;\">provides annual metrological verification of your TX dynamometer, issuing a traceable certificate compliant with ISO 9001.<\/span><\/li>\n<li class=\"whitespace-normal break-words pl-2\"><span style=\"color: #000000;\">Our<\/span> <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.acrn.fr\/en\/after-sales-service\/\">customer service<\/a><\/strong> <span style=\"color: #000000;\">handles maintenance, repairs, and replacement of parts (springs, sliders, Lexan scales) directly in our workshops in Normandy<\/span><\/li>\n<\/ul>\n<\/blockquote>\n","protected":false},"excerpt":{"rendered":"<blockquote><p>The TX mechanical force gauges<\/p><\/blockquote>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The TX mechanical dynamometer is a compact and rugged instrument for measuring tensile forces, designed for heavy-duty use in industrial environments. It works on the principle of the elastic deformation of a spring housed in a steel casing, without any delicate electronic components. Its design makes it completely impervious to temperature fluctuations and adverse weather conditions, allowing it to be used in laboratories, on production sites, or outdoors.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">A built-in safety stop prevents damage in the event of accidental overload, and the maximum release index allows the peak value to be retained after the test without maintaining the load. The TX series covers ranges from 60 to 600 daN (approximately 61 to 612 kg), with an accuracy of \u00b14% and a usable reading starting at 1\/10 of the full scale.<\/p>\n<p><a href=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2026\/04\/Data_Sheet_TX_CX_GB_V2.pdf\" target=\"_blank\" rel=\"noopener\">Technical Specifications: TX Mechanical Tensile Tester<\/a><\/p>\n<p><a href=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2026\/04\/Notice_Instruction_TX-CX__EN.pdf\">Instruction Manual<\/a><\/p>\n","protected":false},"featured_media":4205,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"off","_et_pb_old_content":"<h3>Specifications<\/h3>\r\n<strong>\u21d2<\/strong> Robust and economic\r\n\r\n<strong>\u21d2<\/strong> Accuracy of + \/ - 4%\r\n\r\n<strong>\u21d2<\/strong>Useful reading from 1\/10 of the measuring range\r\n\r\n<strong>\u21d2<\/strong> Safety factor of 5\r\n\r\n<strong>\u21d2<\/strong> Index of maximum disengageable\r\n\r\n \r\n<h4 style=\"text-align: center\">CX Compression<\/h4>\r\n<table style=\"border-collapse: collapse;width: 100%;height: 214px\">\r\n<tbody>\r\n<tr style=\"height: 53px\">\r\n<td style=\"width: 33.3333%;height: 53px;text-align: center\">Model<\/td>\r\n<td style=\"width: 33.3333%;height: 53px;text-align: center\">Scope (daN)<\/td>\r\n<td style=\"width: 33.3333%;height: 53px;text-align: center\">Graduation (daN)<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 60<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 60<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">1<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 100<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 100<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">1<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 150<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to150<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">2<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 200<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 200<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">2<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 300<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 300<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">5<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 400<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 400<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">4<\/td>\r\n<\/tr>\r\n<tr style=\"height: 23px\">\r\n<td style=\"width: 33.3333%;height: 23px\">CX 600<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">0 to 600<\/td>\r\n<td style=\"width: 33.3333%;height: 23px\">20<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>","_et_gb_content_width":""},"product_brand":[],"product_cat":[150],"product_tag":[],"class_list":{"0":"post-6157","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-mechanical-dynamometers","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product\/6157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media\/4205"}],"wp:attachment":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media?parent=6157"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_brand?post=6157"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_cat?post=6157"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_tag?post=6157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}