{"id":6119,"date":"2021-04-01T07:16:58","date_gmt":"2021-04-01T07:16:58","guid":{"rendered":"https:\/\/www.acrn.fr\/product\/ip-xport"},"modified":"2025-09-09T15:07:53","modified_gmt":"2025-09-09T13:07:53","slug":"ip-xport-connection-tool","status":"publish","type":"product","link":"https:\/\/www.acrn.fr\/en\/product\/ip-xport-connection-tool\/","title":{"rendered":"IP XPORT"},"content":{"rendered":"<h3>In what situations should IP Xport be used?<\/h3>\n<ul>\n<li>&#8220;Connected Plants&#8221; projects<\/li>\n<li>Centralization of production control data by connectiong control devices to the network.<\/li>\n<li>Archiving on a PC in production station<\/li>\n<li>Implementation of a SPC Plant software or other information system modules<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"size-full wp-image-4287 aligncenter\" src=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Sans-titre-7.png\" alt=\"ip xport\" width=\"800\" height=\"250\" srcset=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Sans-titre-7.png 800w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Sans-titre-7-480x150.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" \/><\/p>\n<div class='content-column one_half'><h3>Includes:<\/h3>\n<ul>\n<li>Cable Serial to Serial<\/li>\n<li>IP Xport Box<\/li>\n<li>5V power supply with adaptater<\/li>\n<li>Connection guide<\/li>\n<li>Communication protocol guide for ACRN devices<\/li>\n<\/ul><\/div>\n<div class='content-column one_half last_column'><h3>Configuration of the serial link<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; height: 92px;\">\n<tbody>\n<tr style=\"height: 23px;\">\n<td style=\"width: 50%; height: 23px; text-align: center;\">Data bits<\/td>\n<td style=\"width: 50%; height: 23px; text-align: center;\">5,6,7,8<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 50%; height: 23px; text-align: center;\">Stop bits<\/td>\n<td style=\"width: 50%; height: 23px; text-align: center;\">1,2<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 50%; height: 23px; text-align: center;\">Check bit<\/td>\n<td style=\"width: 50%; height: 23px; text-align: center;\">None, Even, Odd, Space, Mark<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"width: 50%; height: 23px; text-align: center;\">Baud rate<\/td>\n<td style=\"width: 50%; height: 23px; text-align: center;\">600 bps~230.4Kbps<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div><div class='clear_column'><\/div>\n<p><img decoding=\"async\" class=\"size-full wp-image-4190 aligncenter\" src=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Autres-schemas-IP-XPort.png\" alt=\"Schema Ip Xport\" width=\"750\" height=\"350\" srcset=\"https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Autres-schemas-IP-XPort.png 750w, https:\/\/www.acrn.fr\/wp-content\/uploads\/2021\/04\/Autres-schemas-IP-XPort-480x224.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 750px, 100vw\" \/><\/p>\n<div class='content-column one_half'><h3>Hardware compatibility:<\/h3>\n<ul>\n<li>Torquemeters NBA, and NCA<\/li>\n<li>Terminal XA et XAm<\/li>\n<li>Vacuum box CTEX<\/li>\n<li>Tube seal tester ATS-X<\/li>\n<li>Aerosol pressure controler PA-X<\/li>\n<\/ul><\/div>\n<div class='content-column one_half last_column'><h3>Ethernet Specifications<\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\">Work mode<\/td>\n<td style=\"width: 50%;\">TCP Serveur, TCP, UDP Client, UDP Serveur, HTTPD Client<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Maximum client IP<\/td>\n<td style=\"width: 50%;\">16 clients max in server mode<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">DHCP supported<\/td>\n<td style=\"width: 50%;\">Yes<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">Connexion control<\/td>\n<td style=\"width: 50%;\">Heartbeat functionnality<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div><div class='clear_column'><\/div>\n","protected":false},"excerpt":{"rendered":"<blockquote><p>Communicate with your ACRN devices in ethernet \/ IP<\/p><\/blockquote>\n<p>IPXPORT lets you pass information from a serial port (COM port) of an ACRN machines to an Ethernet network.<\/p>\n<p>In a few moments, connect your devices to your network.<\/p>\n<p>You can take advantage of the features of the <strong>communication protocol of ACRN devices<\/strong>:<\/p>\n<ul>\n<li>Sending of the measured value on pulse, automatically or on interrogation<\/li>\n<li>Time stamp, unit, &#8230;<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4188,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[160],"product_tag":[],"class_list":{"0":"post-6119","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-unclassified","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product\/6119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media\/4188"}],"wp:attachment":[{"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/media?parent=6119"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_brand?post=6119"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_cat?post=6119"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.acrn.fr\/en\/wp-json\/wp\/v2\/product_tag?post=6119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}